MINI PILES |
SPECIFICATION FOR PRE-FILLED STEEL TUBES
NOTES ON STEEL TUBES> Steel tubes are ideally suited where vibration and/or displacement is to be kept to a minimum.
> In particularly aggressive soils or in tidal zones or where water containing oxygen is known to be flowing round the pile, the steel should be considered sacrificial and the only the concrete SWL should be considered for calculation purposes.
> For piles not exposed to renewed supplies of air and water, temporary or short life pile, the SWL can be taken as the composite value.
> Thick wall top driven piles available to order.
If you have any questions regarding the information found on the website, please feel free to get in touch via one of the methods shown on the left.
|

|
PCF |

|
CONTACT DETAILS
Matthew Russell 157 Shore Road Magheramorne Larne Co. Antrim BT40 3HY
NORTHERN IRELAND
Tel: 028 93 35 35 86
Fax: 028 93 37 22 22
Mob: 07715 32 42 54 07715 32 42 53
Email: j.russell@precastfoundations.org.uk m.russell@precastfoundations.org.uk |
|
PILE PROPERTIES |
UNITS |
|||
|
PILE DIAMETER |
150 |
168 |
220 |
mm |
|
NON-WELDED JOINTS |
|
|||
|
CONCRETE SWL |
19.4 |
23.7 |
41.0 |
Tonnes |
|
CONCRETE AND STEEL SWL |
38.0 |
39.9 |
74.5 |
Tonnes |
|
WELDED JOINTS |
|
|||
|
CONCRETE SWL |
24.2 |
29.3 |
52.0 |
Tonnes |
|
CONCRETE AND STEEL SWL (WELDED) |
43.6 |
49.3 |
84.6 |
Tonnes |
|
STEEL WALL THICKNESS |
3 |
mm |
||
|
STEEL GRADE |
490 |
N/mm2 |
||
|
MODULE SIZES |
1.0/2.0 |
m |
||
|
CONCRETE |
C40 (C50 & C60 TO ORDER) |
N/A |
||
|
AGGREGATE |
20mm CRUSHED BASALT |
N/A |
||
|
STEEL |
BS 4449 WELDABLE GRADE 490 N/mm2 |
N/A
|
||
|
JOINT |
SPIGGOT / ROLL FORMED SOCKET |
N/A |
||
|
WELDING METHOD |
ARC (FLUX COATED RODS) |
N/A
|
||
|
PILE CAP |
PREFAB CAGE AVAILABLE |
N/A |
||